22-Agric-A5 Principles of Instrumentation · May 2017
Nivaar worked solution (AI-drafted; not reviewed by a licensed engineer)
National Exams, 04-Agric-A5, Principles of Instrumentation. 3 hours, open book. Questions 1 and 2 are mandatory (20 marks each); candidates select any THREE of Questions 3–7 (20 marks each) for the official 100-mark paper — all FIVE optional questions are answered below so this set is a complete study resource.
Reference texts: Doebelin, Measurement Systems: Application and Design, 5th ed.; Bentley, Principles of Measurement Systems, 4th ed.; Horowitz & Hill, The Art of Electronics, 3rd ed.; Fraden, Handbook of Modern Sensors, 5th ed.; Skoog, Holler & Crouch, Principles of Instrumental Analysis, 7th ed.
Question text not reproduced: the examination questions are © Engineers and Geoscientists BC. Open the official past paper (linked at the top of this page) to read the question, then follow the worked solution below.
a) A thermocouple's output voltage depends on the TEMPERATURE DIFFERENCE between the measuring (hot) junction and the reference (cold) junction, not on the measuring junction's absolute temperature alone — standard thermocouple voltage-vs-temperature tables are referenced to a 0°C cold junction, which classically was maintained physically by an ice bath. Cold junction compensation (CJC) corrects for whatever temperature the reference junction is ACTUALLY at. Without ice, this is done electronically: an independent local temperature sensor (a thermistor or IC sensor) measures the real (ambient) temperature at the point where the thermocouple wire meets the copper measurement circuitry, and the instrument adds a correction voltage — equal to what a thermocouple of the same type would generate between 0°C and that measured reference temperature — to the raw thermocouple EMF before converting it to a temperature reading, effectively synthesizing a virtual 0°C reference electronically.
b) A thermocouple junction is an inherently LOW-IMPEDANCE source — a simple junction of two dissimilar metal wires, typically only a few ohms to a few tens of ohms — and thermal (Johnson) noise voltage scales with the SQUARE ROOT of the source resistance, $v_n=\sqrt{4k_BTRB}$. Even though the useful thermocouple signal is small (tens of microvolts per °C), the intrinsic noise floor set by its own low resistance is smaller still, so the signal-to-noise ratio stays favourable despite the small absolute signal level; the low output impedance also makes a thermocouple relatively immune to capacitively-coupled interference compared with a high-impedance sensor.
c) Given. Small cylindrical thermocouple bead: length $L=2\ \text{cm}=0.02\ \text{m}$, diameter $D=0.5\ \text{cm}=0.005\ \text{m}$, density $\rho=5000\ \text{kg/m}^3$, specific heat capacity $c=350\ \text{J}/(\text{kg}\cdot\text{K})$, convective heat transfer coefficient $h=50\ \text{J}/(\text{s}\cdot\text{m}^2\cdot\text{K})$.
Find. The thermal time constant $\tau$ of the bead in moving air.
Approach. Treat the bead as a lumped thermal capacitance ($mc$) losing heat to the air by convection ($hA$); the resulting first-order energy balance gives $\tau=mc/(hA)$, so compute the bead's volume, mass, and full (lateral $+$ two end caps) surface area, then combine.
d) Approach. A first-order sensor's response to a step input follows $\theta(t)=1-e^{-t/\tau}$; setting $\theta=0.95$ and solving for $t/\tau$ gives the universal (geometry-independent) multiple of $\tau$ needed for 95% of the ultimate response.
| Quantity | Result |
|---|---|
| Bead volume $V$ | $3.927\times10^{-7}\ \text{m}^3$ |
| Bead mass $m$ | $1.9635\times10^{-3}\ \text{kg}$ |
| Convective surface area $A$ | $3.534\times10^{-4}\ \text{m}^2$ |
| Thermal time constant $\tau$ | $38.9\ \text{s}$ |
| Time to reach 95% of ultimate response | $3.0\,\tau \approx 116.6\ \text{s}$ |