Question 4 of 4: Parallel galvanized-iron pipe loop, dead pump as a fixed loss

Nivaar worked solution (AI-drafted; not reviewed by a licensed engineer)

Notes on this paper

Paper format. National Exams, May 2015 — 04-Bio-A7, 3 hours, open book (any non-communicating calculator permitted). Four questions constitute a complete exam paper, each of equal value, and all require calculation. All four are solved here.

Check — subject-identity note: every page of the paper is headed and footed “04-Bio-A7, Fluid Mechanics” and all four questions (centrifugal-pump performance and similarity scaling, a multi-fluid manometer, laminar pipe flow between two reservoirs, and a turbulent parallel-pipe network) are genuine Fluid Mechanics content, with no bioinstrumentation, signal-processing, or physiological material at all. This solution follows the paper's true subject and cites a fluid-mechanics reference accordingly.

Reference texts. White, Fluid Mechanics, 8th ed. (manometry, laminar Hagen–Poiseuille pipe flow, turbulent Darcy–Weisbach/Colebrook pipe networks, and centrifugal-pump performance & similarity — ch. 2, 6, 11).

Question 4: Parallel galvanized-iron pipe loop, dead pump as a fixed loss (20 marks)

Question text not reproduced: the examination questions are © Engineers and Geoscientists BC. Open the official past paper (linked at the top of this page) to read the question, then follow the worked solution below.

Given.

QuantityPipe 1Pipe 2 (dead pump branch)
Length L60 m55 m
Diameter D5 cm4 cm

Roughness ε=0.15 mm (galvanized iron); water at 20°C, ρ=998 kg/m³, μ=0.001 Pa·s; total flow $Q_{tot}=0.036$ m$^3$/s splits between the two pipes and recombines; the idle pump in pipe 2's branch acts as a fixed minor loss, $K=1.5$.

Find. (a) $Q_1$ and $Q_2$; (b) the overall pressure drop across the parallel combination.

Q=0.036 m³/s Pipe 1: L₁=60 m, D₁=5 cm Pump (off), K=1.5 Pipe 2: L₂=55 m, D₂=4 cm Q=0.036 m³/s Parallel galvanized-iron pipe loop (water, 20°C)
Parallel pipe loop: the two branches share the same start and end nodes, so their head losses must be equal.

Approach. The two pipes share both end nodes, so their head losses must be equal: $h_1(Q_1)=h_2(Q_{tot}-Q_1)$, each evaluated with the Darcy–Weisbach equation and the Colebrook friction factor (plus the pump's $K=1.5$ minor loss in branch 2), with $Q_1+Q_2=Q_{tot}$. Solve iteratively for the split, then recover the pressure drop from either branch.

  1. Set up the governing equations. $$h_1 = f_1\frac{L_1}{D_1}\frac{V_1^2}{2g}, \qquad h_2 = \left(f_2\frac{L_2}{D_2}+K\right)\frac{V_2^2}{2g}, \qquad h_1=h_2, \qquad Q_1+Q_2=0.036$$ with $f$ from Colebrook, $\dfrac{1}{\sqrt f}=-2\log_{10}\!\left(\dfrac{\varepsilon/D}{3.7}+\dfrac{2.51}{Re\sqrt f}\right)$, iterated to convergence at each trial split.
  2. Iterate the flow split. Guessing $Q_1$, computing $V_1=Q_1/A_1$, $Re_1$, $f_1$ (Colebrook), and $h_1$; doing the same for pipe 2 with $Q_2=0.036-Q_1$ and the added $K=1.5$; and adjusting $Q_1$ until $h_1=h_2$ converges to $$\boxed{Q_1 = 0.02296\ \text{m}^3/\text{s} = 22.96\ \text{L/s} \ (63.8\%), \qquad Q_2 = 0.01304\ \text{m}^3/\text{s} = 13.04\ \text{L/s}\ (36.2\%)}$$ which indeed sums to the given 0.036 m$^3$/s.
  3. Report the converged branch state. Pipe 1: $V_1=11.69$ m/s, $Re_1\approx5.84\times10^5$, $f_1\approx0.0264$. Pipe 2: $V_2=10.38$ m/s, $Re_2\approx4.14\times10^5$, $f_2\approx0.0282$. Both flows are fully turbulent (rough-pipe regime), consistent with using Colebrook rather than a laminar formula. Pipe 1 carries the larger share because it has both the larger diameter and no added loss coefficient.
  4. Compute the overall pressure drop (part b). The common head loss is $h=h_1=h_2\approx220.8$ m, so $$\boxed{\Delta p = \rho g h = (998)(9.81)(220.8) = 2.162\times10^{6}\ \text{Pa} \approx 2.16\ \text{MPa}}$$
Check — velocity magnitude. The converged velocities (≈10–12 m/s) and pressure drop (≈2.16 MPa) are unusually high for a typical service pipe, but they follow directly and consistently from the stated total flow rate (0.036 m³/s, i.e. 36 L/s) forced through small-diameter (4–5 cm) pipes — both branches converge to the identical head loss (220.8 m) as required for a true parallel connection, and $Q_1+Q_2$ reproduces the given total exactly, so the result is taken as given rather than adjusted.
QuantityValue
(a) Flow rate, pipe 122.96 L/s (63.8% of total)
(a) Flow rate, pipe 213.04 L/s (36.2% of total)
Velocities V1, V211.69 m/s, 10.38 m/s
Common head loss h220.8 m
(b) Overall pressure drop2.16 MPa